[Params] Model=Yaskawa VS-V7 ;------------------------------------------------------------------------------- name0=n range0=1-39,50-59,80 fill0=000 len0=3 base0=$100 ;=> n001-n041,n050,n104 ;------------------------------------------------------------------------------- name1=r range1=1-2,9,32-36,39-40,42-45,49,61 fill1=000 len1=3 base1=$0 ;------------------------------------------------------------------------------- ; n=Name ; i=internal index (default = base + num_value, default base = 0) ; t=type, L=list, D=double, B=bitfield, +O=operation (no ini-file) ; +R=read only (no ini-file) ; m=multiplier (only for D-type, default 1) ; r=range (default L: 0-1, D: 0-100) ; u=unit (only for D-type, default none) ; f=factory setting (default 0) ; h=Header over list (only for L-type, default none) ; 0=list selection 0 ; 1=list selection 1, default=previous ;------------------------------------------------------------------------------- ;------------------------------------------------------------------------------- [Names] NameRun=r001 NameHz=r002 NameOutWrite=r009 NameOutRead=r032 NameInRead=r043 NameInWrite=r001 NameInvStatus=r044 NameReadA=r039 NameReadV=r040 NameFreqRef=r035 NameReadHz=r036 NameMaxHz=n011 NameMinHz=n016 NameAccTime=n019 NameDecTime=n020 NameMaxA=n036 NameMaxV=n012 cInvFault=$4000 cResetBit=$0008 cInCount=7 InputNames=S1,S2,S3,S4,S5,S6,S7 OutputNames=MA-MC,P1-PC,P2-PC cInReadShift=0 cInWriteShift=4 cInWriteStart=0 cOutCount=3 cOutReadShift=5 cOutWriteShift=0 ;------------------------------------------------------------------------------- ; n=Name ; i=internal index (default = base + num_value, default base = 0) ; t=type, L=list, D=double, B=bitfield, +O=operation (no ini-file) ; +R=read only (no ini-file) ; m=multiplier (only for D-type, default 1) ; r=range (default L: 0-1, D: 0-100) ; u=unit (only for D-type, default none) ; f=factory setting (default 0) ; h=Header over list (only for L-type, default none) ; 0=list selection 0 ; 1=list selection 1, default=previous ;------------------------------------------------------------------------------- [n001] n=Password t=L r=0-4,6,8-13,15,20 f=1 0=The constant n001 can be set and referred and the constant n002-179 can be referred. 1=The constant n001-039 can be read and set 2=The constant n001-067 can be read and set 3=The constant n001-113 can be read and set 4=The constant n001-179 can be read and set 6=Clear fault record only 8=2-Wire Init 9=3-Wire Init 10=2-Wire Init (US) 11=3-Wire Init (US) 12=2-Wire Init (Eur) 13=3-Wire Init (Eur) 15=All parameters can be read and set 20=Init all params to Factory defaults ;------------------------------------------------------------------------------- [n002] n=Control Method t=L f=0 0=V/F Control 1=Open Loop Vector ;------------------------------------------------------------------------------- [n003] n=Operation method t=L r=0-3 f=1 0=Digital Operator 1=Terminal 2=Serial C0mmunication 3=Option PCB ;------------------------------------------------------------------------------- [n004] n=Reference Selection t=L r=0-7 f=2 0=Digital Operator 1=Freq ref.1 (n024) 2=Voltage ref (0-10v) 3=Current ref (4-20 mA) 4=Current ref (0-20 mA) 5=Pulse Train Reference 6=Serial Communication 7=Option PCB ;------------------------------------------------------------------------------- [n005] n=Stop Method Selection t=L r=0-1 f=0 0=Ramp to a stop 1=Coast to a stop ;------------------------------------------------------------------------------- [n006] n=Reverse Prohibit t=L f=0 h=Reverse rotation 0=enabled 1=disabled ;------------------------------------------------------------------------------- [n007] n=Stop Key Selection t=L f=0 0=Stop key enabled 1=Active only when n003=0 ;------------------------------------------------------------------------------- [n008] n=Frequency Reference Selection Local t=L f=0 0=Freq. Ref. from Digital Operator 1=Freq. Ref from n024 ;------------------------------------------------------------------------------- [n009] n=Freq. ref. Enter req. t=L f=0 0=Enter req. to accept 1=No Enter req. ;------------------------------------------------------------------------------- [n010] n=Operator Connection Detect t=L f=0 0=Disabled 1=Enabled (Operator Connection fault detect) ;------------------------------------------------------------------------------- [n011] n=Max.Output Frequency t=D m=0.1 r=50.0-400.0 u=Hz f=60.0 ;------------------------------------------------------------------------------- [n012] n=Max Voltage t=D m=0.1 r=0.1-510.0 u=V f=460.0 ;------------------------------------------------------------------------------- [n013] n=Max Voltage output Frequency t=D m=0.1 r=0.2-400.0 u=Hz f=60.0 ;------------------------------------------------------------------------------- [n014] n=Mid Output Frequency t=D m=0.1 r=0.1-399.9 u=Hz f=1.5 ;------------------------------------------------------------------------------- [n015] n=Mid. Frequency Voltage t=D m=0.1 r=0.1-510.0 u=V f=24.0 ;------------------------------------------------------------------------------- [n016] n=Min. Output Frequency t=D m=0.1 r=0.1-10.0 u=Hz f=1.5 ;------------------------------------------------------------------------------- [n017] n=Min. Output Frequency Voltage t=D m=0.1 r=0.1-50.0 u=V f=24.0 ;------------------------------------------------------------------------------- [n018] n=Accel/Decel time unit t=L r=0-1 f=0 0=0.1 s 1=0.01 s [n019] n=Accel Time 1 t=D m=0.1 r=0.0-999.9 u=sec f=10.0 ;------------------------------------------------------------------------------- [n020] n=Decel Time 1 t=D m=0.1 r=0.0-999.9 u=sec f=10.0 ;------------------------------------------------------------------------------- [n021] n=Accel Time 2 t=D m=0.1 r=0.0-999.9 u=sec f=10.0 ;------------------------------------------------------------------------------- [n022] n=Decel Time 2 t=D m=0.1 r=0.0-999.9 u=sec f=10.0 ;------------------------------------------------------------------------------- [n023] n=S-curve Characteristics Time Selection t=L r=0-3 f=1 0=Not provided 1=0.2 sec 2=0.5 sec 3=1.0 sec ;------------------------------------------------------------------------------- [n024] n=Frequency Ref. 1 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n025] n=Frequency Ref. 2 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n026] n=Frequency Ref. 3 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n027] n=Frequency Ref. 4 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n028] n=Frequency Ref. 5 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n029] n=Frequency Ref. 6 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n030] n=Frequency Ref. 7 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n031] n=Frequency Ref. 8 t=D m=0.01 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n032] n=Jog Frequency Reference t=D m=0.01 r=0.0-360.0 u=Hz f=6.0 ;------------------------------------------------------------------------------- [n032] n=Jog Frequency Reference t=D m=0.01 r=0.0-360.0 u=Hz f=6.0 ;------------------------------------------------------------------------------- [n033] n=Frequency Refer. upper limit t=D m=0.1 r=0.0-110 u=% f=100.0 ;------------------------------------------------------------------------------- [n034] n=Frequency Refer. lower limit t=D m=0.1 r=0.0-110 u=% f=0 ;------------------------------------------------------------------------------- [n035] n=Unit Selection of Frequency t=L r=0-2 f=0 0=0.01 Hz 1=0.1% 2=1/min ;------------------------------------------------------------------------------- [n036] n=Motor Rated Current t=D m=0.1 r=0.0-1000.0 u=A f=6 ;------------------------------------------------------------------------------- [n037] n=Electronic Motor Overload Protection t=L f=0 r=0-2 0=Standard Motor 1=Standard Motor - Short Term 2=Disbaled ;------------------------------------------------------------------------------- [n038] n=Motor Overload Protection Time Constant t=D f=8 M=1 u=Min ;------------------------------------------------------------------------------- [n039] n=Cooling Fan Operation t=L f=0 r=0-1 0=Operates only when Drive is running 1=operates with power is ON ;------------------------------------------------------------------------------- [n050] n=Multi-function Input Terminal S1 t=L f=1 r=1-25 1=Run fwd (2 wire) 1=Run rev (2 wire) 3=External fault (Normally open) 4=External fault (Normally closed) 5=Fault reset 6=Multi-Speed ref 1 7=Multi-Speed ref 2 8=Multi-Speed ref 3 9=Multi-Speed ref 4 10=Jog frequency selection 11=Accel/Decel time switch 12=External baselock reference (Normally open) 13=External baselock reference (Normally closed) 14=Search command from Max. frequency 15=Search command from setting frequency 16=Accel/Decel hold 17=Local/Remote switch 18=Serial/Terminal switch 19=Emergency Stop Fault (NO, Stop n005) 20=Emergency Stop Alarm (NO, Stop n005) 21=Emergency Stop Fault (NC, Stop n005) 22=Emergency Stop Alarm (NC, Stop n005) 23=PID control cancel 24=PID integral value reset 25=PID integral hold ;------------------------------------------------------------------------------- [n051] n=Multi-function Input Terminal S2 t=L f=2 r=1 1=[n050]1-25 ;------------------------------------------------------------------------------- [n052] n=Multi-function Input Terminal S3 t=L f=3 r=0-1 0=Forward/Reverse 1=[n050]1-25 ;------------------------------------------------------------------------------- [n053] n=Multi-function Input Terminal S4 t=L f=5 r=1 1=[n050]1-25 ;------------------------------------------------------------------------------- [n054] n=Multi-function Input Terminal S5 t=L f=6 r=1 1=[n050]1-25 ;------------------------------------------------------------------------------- [n055] n=Multi-function Input Terminal S6 t=L f=7 r=1 1=[n050]1-25 ;------------------------------------------------------------------------------- [n056] n=Multi-function Input Terminal S7 t=L f=10 r=1,34,35 1=[n050]1-25 34=UP/DOWN command (S7=UP, S6=DOWN) 35=Self-dignostic test (MODBUS Communication) ;------------------------------------------------------------------------------- [n057] n=Multi-function Output Terminal MA-MB-MC t=L f=0 r=0-7,10-19 0=Fault 1=During run 2=Frequency agreed 3=Zero speed 4=Frequency detection (out Hz <= n095 Hz) 5=Frequency detection (out Hz >= n095 Hz) 6=During overtorque detection (Normally open) 7=During overtorque detection (Normally closed) 10=Minor fault 11=During baselock 12=Run mode 13=Inverter ready operation 14=Fault retry 15=Undervoltage 16=Reverse 17=Speed search 18=Serial communication 19=During PID loss ;------------------------------------------------------------------------------- [n058] n=Multi-function Output Terminal P1-PC t=L f=1 r=0 0=[n057]0-19 ;------------------------------------------------------------------------------- [n059] n=Multi-function Output Terminal P2-PC t=L f=2 r=0 0=[n057]0-19 ;------------------------------------------------------------------------------- [n080] n=Carrier frequency t=L f=3 r=1-4,7-9 1= 2.5 kHz 2= 5 kHz 3= 7.5 kHz 4= 10 kHz 7=12f 8=24f 9=36f ;------------------------------------------------------------------------------- [?104] n=Stop method at comm error t=L f=1 r=0-3 0=Ramp to stop - Decel 1 1=Coast to stop 2=Ramp to stop - Decel 2 3=Continue operation (alarm) ;------------------------------------------------------------------------------- ; Operation inputs/outputs ;------------------------------------------------------------------------------- [r001] n=Run Operation Signal t=BO r=0-10 0=Run Command|Stop|Run 1=Reverse Command|FWD|REV 2=Extrenal Fault|No|Yes 3=Fault Reset|No|Yes 4=Multi-function input S1|0|1 5=Multi-function input S2|0|1 6=Multi-function input S3|0|1 7=Multi-function input S4|0|1 8=Multi-function input S5|0|1 9=Multi-function input S6|0|1 10=Multi-function input S7|0|1 ;------------------------------------------------------------------------------- [r002] n=Frequency reference t=DO m=0.01 r=0.0-400.0 u=Hz ;------------------------------------------------------------------------------- [r009] n=Multi-function Output t=BO r=0-1 0=Multi-function output MA-MC|0|1 1=Multi-function output P1-PC|0|1 2=Multi-function output P2-PC|0|1 ;------------------------------------------------------------------------------- [r032] n=Status Signal t=BR r=0-7 0=During|Stop|Run 1=During|FWD|REV 2=Inverter operation|not ready|ready 3=Fault|no|Major 4=Data setting|ON|Error 5=Multi-function output MA-MC|0|1 6=Multi-function output P1-PC|0|1 6=Multi-function output P2-PC|0|1 ;------------------------------------------------------------------------------- [r033] n=Monitor data t=BR r=0-3,6-15 0=Overcurrent,etc (OC)|no|YES 1=Overvoltage (OV)|no|YES 2=Inverter overloaded (OL2)|no|YES 3=Inverter overheat (OH) |no|YES 6=PID Feedpack (FpL)|no|YES 7=External fault (STP)|no|YES 8=Hardware fault (Fxx)|no|YES 9=Motor overload (OL1)|no|YES 10=Overtorque (OL2)|no|YES 11=Undertorque (OL3)|no|YES 12=Pover loss (UV1)|no|YES 13=Control power supply fault (UV2)|no|YES 14=Memobus communication fault (CE)|no|YES 15=Operator connection fault (OPR)|no|YES ;------------------------------------------------------------------------------- [r034] n=Data link status t=BR r=0,3-4 0=Data write in|no|YES 3=Upper/lower limit fault|no|YES 4=Matching fault|no|YES ;------------------------------------------------------------------------------- [r035] n=Frequency reference t=DR m=0.01 u=Hz ;------------------------------------------------------------------------------- [r036] n=Output frequency t=DR m=0.01 u=Hz ;------------------------------------------------------------------------------- [r039] n=Output Current t=DR m=0.1 u=A ;------------------------------------------------------------------------------- [r040] n=Output voltage t=DR m=1.0 u=V ;------------------------------------------------------------------------------- [r043] n=External terminal input value t=BR r=0-6 0=S1|0|1 1=S2|0|1 2=S3|0|1 3=S4|0|1 4=S5|0|1 5=S6|0|1 6=S7|0|1 ;------------------------------------------------------------------------------- [r044] n=Inverter status t=BR r=0-15 0=During|stop|run 1=During zero speed|no|YES 2=Frequency agreed|no|YES 3=Minor fault|no|YES 4=Frequency detection n095|>|<= 5=Frequency detection n095|<|>= 6=Inverter operation|not ready|ready 7=During undervoltage|no|YES 8=Baselock|no|YES 9=Frequency mode|serial|terminal 10=Run mode|communication|terminal 11=Overtorque|no|YES 12=Undertorque|no|YES 13=Fault retry|no|YES 14=Major fault|no|YES 15=Communication|ok|FAULT ;------------------------------------------------------------------------------- [r045] n=Multifunction contact output monitor t=BR r=0-2 0=MA-MC|0|1 1=P1-PC|0|1 2=P2-PC|0|1 ;------------------------------------------------------------------------------- [r049] n=Main circuit DC voltage t=DR m=1.0 u=V ;------------------------------------------------------------------------------- [r061] n=Communication error t=BR r=0-1,3-6 0=CRC error|no|YES 1=Data length error|no|YES 3=Parity error|no|YES 4=Overrun error|no|YES 5=Frame error|no|YES 6=Time-over|no|YES ;------------------------------------------------------------------------------- [?003] n=Input Voltage t=D m=0.1 r=150.0-510.0 u=V f=200.0 ;------------------------------------------------------------------------------- [?005] n=FWD Command Direction selection t=L f=0 h=Direction of the motor rotation can be reversed 0=no 1=yes ;------------------------------------------------------------------------------- [?010] n=V/f Pattern Selection t=L r=0-15,255 f=1 h=n012-018 can be set at 15 and 255 selection 0=50 Hz, gen 1=60/60 Hz, gen 2=60/50 Hz, gen 3=72,60 Hz, gen 4=50 Hz, var. mom 1 5=50 Hz, var. mom 2 6=60 Hz, var. mom 3 7=60 Hz, var. mom 4 8=50 Hz, big start moment, smaller 9=50 Hz, big start moment, bigger 10=60 Hz, big start moment, smaller 11=60 Hz, big start moment, bigger 12=90/60 Hz 13=120/60 Hz 14=180/60 Hz 15=Desired V/f pattern (Output voltage limit effective), def 60/60 Hz 255=Desired V/f pattern (Output voltage limit ineffective) ;------------------------------------------------------------------------------- [?011] n=Motor Rated Voltage t=D m=0.1 r=150.0-510.0 u=V f=200.0 ;-------------------------------------------------------------------------------