[Params] Model=Yaskawa VS-616PC5/P5 ;------------------------------------------------------------------------------- name0=n range0=1-41,50,104 fill0=000 len0=3 base0=$100 ;=> n001-n041,n050,n104 ;------------------------------------------------------------------------------- name1=r range1=1-2,9,32-36,39-40,42-45,49,61 fill1=000 len1=3 base1=$0 ;------------------------------------------------------------------------------- ; n=Name ; i=internal index (default = base + num_value, default base = 0) ; t=type, L=list, D=double, B=bitfield, +O=operation (no ini-file) ; +R=read only (no ini-file) ; m=multiplier (only for D-type, default 1) ; r=range (default L: 0-1, D: 0-100) ; u=unit (only for D-type, default none) ; f=factory setting (default 0) ; h=Header over list (only for L-type, default none) ; 0=list selection 0 ; 1=list selection 1, default=previous ;------------------------------------------------------------------------------- [n001] n=Password t=L r=0-3,6-9,616 f=1 0=The constant n001 can be set and referred and the constant n002-108 can be referred. 1=The constant n001-034 can be set and referred and constant n035-108 can be referred. 2=The constant n001-049 can be set and referred and constant n050-108 can be referred. 3=The constant n001-199 can be set and referred 6=Initializing (for Japan, 2 wire sequence) 7=Initializing (for Japan, 3 wire sequence) 8=Initializing (for USA, 2 wire sequence) 9=Initializing (for USA, 3 wire sequence) 616=All constants can be set and referred. ;------------------------------------------------------------------------------- [n002] n=Run Signal Selection t=L r=0-8 f=3 h=Run Command Frequency Reference 0=Operator\t Operator 1=Terminal\t Operator 2=Operator\t Terminal 3=Terminal\t Terminal 4=Operator\t Communication 5=Terminal\t Communication 6=Communication\t Communication 7=Communication\t Operator 8=Communication\t Terminal ;------------------------------------------------------------------------------- [n003] n=Input Voltage t=D m=0.1 r=150.0-510.0 u=V f=200.0 ;------------------------------------------------------------------------------- [n004] n=Stop Method Selection t=L r=0-3 f=0 0=Deceleration to a stop 1=Coasting to a stop 2=Coasting to a stop with timer (After STOP command is input, RUN command is effective) 3=Coasting to a stop with timer (Always RUN command is effective) ;------------------------------------------------------------------------------- [n005] n=FWD Command Direction selection t=L f=0 h=Direction of the motor rotation can be reversed 0=no 1=yes ;------------------------------------------------------------------------------- [n006] n=Reverse Prohibit Selection t=L f=1 h=Reverse rotation 0=enabled 1=disabled ;------------------------------------------------------------------------------- [n007] n=Operator Remote/Local Selection t=L f=1 h=Remote/Local Selection 0=ineffective 1=effective ;------------------------------------------------------------------------------- [n008] n=Operator Stop Key Selection t=L f=1 0=Effective only during operation with operator run command 1=Always effective ;------------------------------------------------------------------------------- [n009] n=Frequency Reference Setting Method Selection t=L f=1 h=Operator frequency reference setting is effective with ENTER key input 0=no 1=yes ;------------------------------------------------------------------------------- [n010] n=V/f Pattern Selection t=L r=0-15,255 f=1 h=n012-018 can be set at 15 and 255 selection 0=50 Hz, gen 1=60/60 Hz, gen 2=60/50 Hz, gen 3=72,60 Hz, gen 4=50 Hz, var. mom 1 5=50 Hz, var. mom 2 6=60 Hz, var. mom 3 7=60 Hz, var. mom 4 8=50 Hz, big start moment, smaller 9=50 Hz, big start moment, bigger 10=60 Hz, big start moment, smaller 11=60 Hz, big start moment, bigger 12=90/60 Hz 13=120/60 Hz 14=180/60 Hz 15=Desired V/f pattern (Output voltage limit effective), def 60/60 Hz 255=Desired V/f pattern (Output voltage limit ineffective) ;------------------------------------------------------------------------------- [n011] n=Motor Rated Voltage t=D m=0.1 r=150.0-510.0 u=V f=200.0 ;------------------------------------------------------------------------------- [n012] n=Max.Output Frequency t=D m=0.1 r=50.0-400.0 u=Hz f=60.0 ;------------------------------------------------------------------------------- [n013] n=Max Voltage t=D m=0.1 r=0.1-510.0 u=V f=200.0 ;------------------------------------------------------------------------------- [n014] n=Max Voltage output Frequency t=D m=0.1 r=0.2-400.0 u=Hz f=60.0 ;------------------------------------------------------------------------------- [n015] n=Mid Output Frequency t=D m=0.1 r=0.1-399.9 u=Hz f=3.0 ;------------------------------------------------------------------------------- [n016] n=Mid. Frequency Voltage t=D m=0.1 r=0.1-510.0 u=V f=15.0 ;------------------------------------------------------------------------------- [n017] n=Min. Output Frequency t=D m=0.1 r=0.1-10.0 u=Hz f=1.5 ;------------------------------------------------------------------------------- [n018] n=Min. Output Frequency Voltage t=D m=0.1 r=0.1-50.0 u=V f=10.0 ;------------------------------------------------------------------------------- [n019] n=Accel Time 1 t=D m=0.1 r=0.0-3600.0 u=sec f=10.0 ;------------------------------------------------------------------------------- [n020] n=Decel Time 1 t=D m=0.1 r=0.0-3600.0 u=sec f=10.0 ;------------------------------------------------------------------------------- [n021] n=Accel Time 2 t=D m=0.1 r=0.0-3600.0 u=sec f=10.0 ;------------------------------------------------------------------------------- [n022] n=Decel Time 2 t=D m=0.1 r=0.0-3600.0 u=sec f=10.0 ;------------------------------------------------------------------------------- [n023] n=S-curve Characteristics Time Selection t=L r=0-3 f=1 0=Not provided 1=0.2 sec 2=0.5 sec 3=1.0 sec ;------------------------------------------------------------------------------- [n024] n=Unit Selection of Frequency t=L r=0-2 f=0 0=0.1 Hz 1=0.1% 2=1/min ;------------------------------------------------------------------------------- [n025] n=Frequency Ref. 1 t=D m=0.1 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n026] n=Frequency Ref. 2 t=D m=0.1 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n027] n=Frequency Ref. 3 t=D m=0.1 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n028] n=Frequency Ref. 4 t=D m=0.1 r=0.0-360.0 u=Hz f=0.0 ;------------------------------------------------------------------------------- [n029] n=Jog Frequency Reference t=D m=0.1 r=0.0-360.0 u=Hz f=6.0 ;------------------------------------------------------------------------------- [n032] n=Motor Rated Current t=D m=0.1 r=0.0-1000.0 u=A f=6.0 ;------------------------------------------------------------------------------- [n035] n=Multi-function Input Terminal S2 t=L f=0 r=0-24 0=Reverse running operation command 1=FWD/REW selection 2=External fault (Normally open) 3=External fault (Normally closed) 4=Fault reset 5=Local/Remote changeover 6=Communication/control circuit terminal changeover 7=Emergency stop 8=Input level selection of master speed frequency reference 9=Multi step speed reference 1 10=Multi step speed reference 2 11=Jog frequency selection 12=Accel/Decel time changeover reference 13=External baselock reference (Normally open) 14=External baselock reference (Normally closed) 15=Search command from Max. frequency 16=Search command from setting frequency 17=Constant setting allowable/prohibit 18=PID integral value reset 19=PID control cancel 20=Timer function 21=OH3 (Inverter overheat pre alarm) 22=Analog reference sample/hold 23=KEB reference (Normally open) 24=KEB reference (Normally closed) ;------------------------------------------------------------------------------- [n036] n=Multi-function Input Terminal S3 t=L f=2 r=0 0=[n035]2-24 ;------------------------------------------------------------------------------- [n037] n=Multi-function Input Terminal S4 t=L f=4 r=0 0=[n035]2-24 ;------------------------------------------------------------------------------- [n038] n=Multi-function Input Terminal S5 t=L f=9 r=0 0=[n035]2-24 ;------------------------------------------------------------------------------- [n038] n=Multi-function Input Terminal S6 t=L f=9 r=0 0=[n035]2-24 ;------------------------------------------------------------------------------- [n039] n=Multi-function Input Terminal S6 t=L f=10 r=0,25-26 0=[n035]2-24 25=UP/DOWN command (S5=UP, S6=DOWN) 26=Self-dignostic test (MODBUS Communication) ;------------------------------------------------------------------------------- [n040] n=Multi-function Output Terminal MA-MB-MC t=L f=0 r=0-17 0=Fault 1=During run 2=Frequency agreed 3=Desired frequency agreed 4=Frequency detection (out Hz <= detection Hz) 5=Frequency detection (out Hz >= detection Hz) 6=During overtorque detection (Normally open) 7=During overtorque detection (Normally closed) 8=During baselock 9=Run mode 10=Inverter ready operation 11=Timer function 12=During auto-reset(During fualt retry) 13=OL Pre-alarm (OL1,OL2) 14=During frequency reference missing 15=Data output from PLC 16=During PID feedback missing 17=OH1 alarm ;------------------------------------------------------------------------------- [n041] n=Multi-function Output Terminal M1-M2 t=L f=1 r=0 0=[n040]0-17 ;------------------------------------------------------------------------------- [n050] n=Carrier frequency t=L f=3 r=1-9 1= 2.5 kHz 2= 5 kHz 3= 8 kHz 4= 10 kHz 5=12.5 kHz 6=15 kHz 7=12f 8=24f 9=36f ;------------------------------------------------------------------------------- [n104] n=Stop method at comm error t=L f=1 r=0-3 0=Ramp to stop - Decel 1 1=Coast to stop 2=Ramp to stop - Decel 2 3=Continue operation (alarm) ;------------------------------------------------------------------------------- ; Operation inputs/outputs ;------------------------------------------------------------------------------- [r001] n=Run Operation Signal t=BO r=0-7 0=Run Command|Stop|Run 1=Reverse Command|FWD|REV 2=Extrenal Fault|No|Yes 3=Fault Reset|No|Yes 4=Multi-function input S3|0|1 5=Multi-function input S4|0|1 6=Multi-function input S5|0|1 7=Multi-function input S6|0|1 ;------------------------------------------------------------------------------- [r002] n=Frequency reference t=DO m=0.1 r=0.0-400.0 u=Hz ;------------------------------------------------------------------------------- [r009] n=Multi-function Output t=BO r=0-1 0=Multi-function output MA-MC|0|1 1=Multi-function output M1-M2|0|1 ;------------------------------------------------------------------------------- [r032] n=Status Signal t=BR r=0-6 0=During|Stop|Run 1=During|FWD|REV 2=Inverter operation|not ready|ready 3=Fault|no|Major 4=Data setting|ON|Error 5=Multi-function output MA-MC|0|1 6=Multi-function output M1-M2|0|1 ;------------------------------------------------------------------------------- [r033] n=Monitor data t=BR r=0-3,5-9,12-13 0=Overcurrent,etc|no|YES 1=Overvoltage|no|YES 2=Inverter overloaded|no|YES 3=Inverter overheat|no|YES 5=Main circuit fault|no|YES 6=Braking Tranistor fault|no|YES 7=External fault|no|YES 8=Hardware fault|no|YES 9=Motor overload|no|YES 11=Undervoltage|no|YES 12=Pover loss|no|YES 13=Input/Output phase|no|YES ;------------------------------------------------------------------------------- [r034] n=Data link status t=BR r=0,3-4 0=Data write in|no|YES 3=Upper/lower limit fault|no|YES 4=Matching fault|no|YES ;------------------------------------------------------------------------------- [r035] n=Frequency reference t=DR m=0.1 u=Hz ;------------------------------------------------------------------------------- [r036] n=Output frequency t=DR m=0.1 u=Hz ;------------------------------------------------------------------------------- [r039] n=Output Current t=DR m=0.1 u=A ;------------------------------------------------------------------------------- [r040] n=Output voltage t=DR m=1.0 u=V ;------------------------------------------------------------------------------- [r043] n=External terminal input value t=BR r=0-5 0=S1|0|1 1=S2|0|1 2=S3|0|1 3=S4|0|1 4=S5|0|1 5=S6|0|1 ;------------------------------------------------------------------------------- [r044] n=Inverter status t=BR r=0-12,14-15 0=During|stop|run 1=During zero speed|no|YES 2=Frequency agreed|no|YES 3=Desired frequency agreed|no|YES 4=Frequency detection|>|<= 5=Frequency detection|<|>= 6=Inverter operation|not ready|ready 7=During undervoltage|no|YES 8=During braking|no|YES 9=Frequency mode|communication|terminal 10=Run mode|communication|terminal 11=Overtorque|no|YES 12=Frequency|OK|missing 14=Major fault|no|YES 15=Communication|ok|FAULT ;------------------------------------------------------------------------------- [r045] n=Multifunction contact output monitor t=BR r=0-1 0=MA-MC|0|1 1=M1-M2|0|1 ;------------------------------------------------------------------------------- [r049] n=Main circuit DC voltage t=DR m=1.0 u=V ;------------------------------------------------------------------------------- [r061] n=Communication error t=BR r=0-1,3-6 0=CRC error|no|YES 1=Data length error|no|YES 3=Parity error|no|YES 4=Overrun error|no|YES 5=Frame error|no|YES 6=Time-over|no|YES [FormParamYaskawaPos] Left=217 Top=228 Width=637 Height=381